Water, Vol. 16, Pages 1118: Influence of Structural Symmetry of Fault Zones on Fluid-Induced Fault Slips and Earthquakes

Subsurface fluid injection and extraction can reactivate faults and induce earthquakes. In current research, faults are typically described as symmetrical structures and the presence of asymmetric structures is often overlooked. The reality is that numerous asymmetric faults exist within the Earth’s crust. The architectural and permeability characteristics of fault zones differ significantly between symmetrical and asymmetrical faults. These differences may have a great influence on fault stability during fluid injection or extraction. In this study, the impact of fault zone structures on fluid-induced slips and seismic activity were investigated through numerical analysis. The findings indicated that symmetrical faults were more likely to induce larger slips and earthquakes during various subsurface fluid operations. For asymmetric faults, larger induced slips occurred when fluid was operated in a hanging wall reservoir than in a footwall reservoir. In symmetrical faults, the opposite was true. When evaluating the stability of a fault in subsurface fluid engineering, the fault structure and fluid pattern and their combined effects must be considered comprehensively.

Apr 23, 2024 - 21:32
 0  158
Water, Vol. 16, Pages 1118: Influence of Structural Symmetry of Fault Zones on Fluid-Induced Fault Slips and Earthquakes

Water, Vol. 16, Pages 1118: Influence of Structural Symmetry of Fault Zones on Fluid-Induced Fault Slips and Earthquakes

Water doi: 10.3390/w16081118

Authors: Zhiyong Niu Bing Bai

Subsurface fluid injection and extraction can reactivate faults and induce earthquakes. In current research, faults are typically described as symmetrical structures and the presence of asymmetric structures is often overlooked. The reality is that numerous asymmetric faults exist within the Earth’s crust. The architectural and permeability characteristics of fault zones differ significantly between symmetrical and asymmetrical faults. These differences may have a great influence on fault stability during fluid injection or extraction. In this study, the impact of fault zone structures on fluid-induced slips and seismic activity were investigated through numerical analysis. The findings indicated that symmetrical faults were more likely to induce larger slips and earthquakes during various subsurface fluid operations. For asymmetric faults, larger induced slips occurred when fluid was operated in a hanging wall reservoir than in a footwall reservoir. In symmetrical faults, the opposite was true. When evaluating the stability of a fault in subsurface fluid engineering, the fault structure and fluid pattern and their combined effects must be considered comprehensively.

What's Your Reaction?

like

dislike

love

funny

angry

sad

wow

Lema Kefyalew Studying a Ph.D. in Civil Engineering (Hydraulic Engineering). Studying Master of Project Management (MPM). Graduated with MSc in Civil Engineering (Hydraulic Engineering). Followed a 12 month Software Engineering program at ALX_Africa (Holberton school). Graduated with BA degree in Management. Graduated with BSc degree in Civil Engineering.